• 24kv Silicon Rubber Separable Connector
  • 24kv Silicon Rubber Separable Connector
  • 24kv Silicon Rubber Separable Connector
  • 24kv Silicon Rubber Separable Connector
  • 24kv Silicon Rubber Separable Connector
  • 24kv Silicon Rubber Separable Connector

24kv Silicon Rubber Separable Connector

Gender: Rear
Application: Power
Rated Voltage: 24kv
Rated Current: 630/1250A
Cross Section: 25-500 Sqmm
The Highest Operating Voltage: 24kv
Customization:
Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
HCPS-H-24
Transport Package
1 Set/Carton
Specification
KEMA, EN50180, EN50181, DIN47636, IEEE386,IEC60502
Trademark
HiFuture
Origin
Shenzhen, China
HS Code
8538900000
Production Capacity
9000PCS/Month

Product Description

24kv Silicon Rubber Separable Connector

Product Advantage:

1. Adopt imported silicon rubber raw materials and imported equipments to ensure product quality stability.

2. Product design method has achieved international advanced level, which meet the requirement of operation under various working conditions, and reasonable external dimensions which meet the requirement of compact switch cabinet multipath outlet Protection.

3. Each batch of raw materials passes the mechanical performance index spot check, which ensures product quality from the source.

4. All finished products 100% pass factory performance test (power frequency withstand voltage, partial discharge);

5. Dust-free workshop production protects the products from the impact of external environment and ensures the product quality stability;

6.Years of experience in installation and operation, professional engineering installation team, can provide on-site installation and installation guide, ensure the quality during the product installation;

7. Products applicable to 12/20 (24) kV or less of full range of electrical system to isolate and protect inlet and outlet line bushing in power equipments such as switchgear and cable brantch cabinets. 

8. All products conform to IEC 60502, GB12706.4 standards and passed type tests of national authority organization, safe and reliable with long-term operation.


Technical Parameter:
 
                                                    12/20kV(24kV) separable connector technical parameter
12/20kV separable connector     rated voltage 12/20kV
rated current 630A/1250A
 the highest operating voltage 24kV
cable accessories conductor material copper,copper and aluminum
long-time running temperature -40ºC to 95ºC
rated current conductor temperature rise not higher than 95ºC
   short circuit temperature  250ºC,less than 5s
  main insulation material solid silicone rubber
 power frequency withstand voltage 54kV,5min, no flashover, no breakdown
partial discharge  20kV, PD≤5pc 
 impulse voltage test 125kV, ±10 times
 short circuit thermal stability (conductor) 25kA, 2s 2 times, no visiable damage
short circuit dynamic stability 63kA,not less than 10ms,no visiable damage
 screened resistance test before and after aging, screened resistance less than 5000Ω
 screened leakage current under 24kV, leakage current not bigger than 0.5mA
     Got Holland KEMA certificate



Quality Control System

Hifuture devote itself to establish a first grade enterprise and a famous brand. During the operation, production, and management, Hifuture has been implementing the enterprise tenet of "customer first, quality first and people first", and making great effort to build an efficient, progmatic,innovative corporate culture. 

Our commitment:

By providing customers with the excellent, environmental, safe and reliable city and country power distribution network and service to putting an end to non-performing products. Abide by laws and regulations and other requirements.

Improving product quality by constantly improve the equipment, technique lifting, technique improving, production improving and quality management.

And improving product environmental performance through carrying out energy-saving, consumption reduction, emission reduction and pollution prevention. Reducing the potential health and safe problems during the production to prevent and decrease the accident.

All staff participation, clear statement of safe responsibility of quality, environment, and occupational health and safety. Providing effective training and necessary resource to enhance the employee quality and the awareness of environment and occupational health and safety.

Improving staff's qualities and abilities to make sure each employee perform their duty properly and improve their job performance constantly.

Continuous improvement of system operation suitability, adequacy, effectiveness by external and internal audit, management review, take prevented actions. Analyze the experience of quality, environment, health and safety area with the relevant parties. Advance the idea of quality, environment, health and safety.

24kv Silicon Rubber Separable Connector24kv Silicon Rubber Separable Connector24kv Silicon Rubber Separable Connector24kv Silicon Rubber Separable Connector

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
130000000 USD
Plant Area
120000 square meters