36kv Cold Shrink Indoor Terminations

Type: Cold Shrink
Material: Silicone Rubber
Application: Insulation Protection
Character: Insulation
Species: Terminal
Production Process: Cold Pressing
Customization:
Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Shape
Rectangular
Certification
ISO, IEC, GB
Brand
Hifuture
Cross Section
50-630 Sq.M.
Core
Single-Core, Three-Core
Lug Type
Cu, Al, Cual
Features
Excellent Insulation, Anti-Tracking, etc
Transport Package
1 Set/ Carton
Specification
12kV, 24kV, 36kV
Trademark
HiFuture
Origin
Shenzhen, China
HS Code
8538900000
Production Capacity
10000PCS/Month

Product Description

Cold Shrink Indoor Terminations 36kV
Indoor Termination Conductor Cross Section
(mm²)
Cold Shrink Type Premoulded Type 18/30(36)kV 26/35(40.5)kV
HCLN-35-1 HCYN-35-1 50-120 50-95
HCLN-35-2 HCYN-35-2 150-240 120-185
HCLN-35-3 HCYN-35-3 300-630 240-400
HCLN-35-4 HCYN-35-4   500-630
36kv Cold Shrink Indoor Terminations36kv Cold Shrink Indoor Terminations36kv Cold Shrink Indoor Terminations36kv Cold Shrink Indoor Terminations36kv Cold Shrink Indoor Terminations

Cold Shrink Cable Accessories: 
1. Hifuture cold shrinkable cable accessories adopt world renowned brand liquid/solid silicone rubber material. The products are with excellent insulation, anti-tracking, rebound resistance, heat/cold resistance, ozone resistance, anti-aging, and good dielectric properties, and can be used under various harsh conditions.

2. Geometric stress control method.

3. Standards compliance: IEC60502, GB/T12706.4, EN50180& EN50181(C type bushing)

4. Cold installation, easy and safe without using fire, just by pulling the spiral.


Technical Data:
Rated Voltage 18/30(36)kV 26/35(40.5)kV
Running Temperature 36kV 40.5kv
AC Withstand Voltage and DC Withstand Voltage 81kV,5min, or 72kV, 15min, no flashover, no breakdown 117kV, 5min or 104kV, 15 min no flashover, no breakdown
Partial Discharge 30kV, PD≤5pC 45kV, PD≤5pC
Impulse Voltage Test 170kV, ±10 times 200kV, ±10 times
Short Circuit Thermal Stability (Conductor) 23kA, 2s twice, no visible damage 25kA 2s twice, no visible damage
Short Circuit Dynamic Stability 83kA, not less than 10ms, no visible damage 88kA, not less than 10ms, no visible damage
Constant Voltage Load Cycle apply voltage 1.25U0 to conductor and heat to(90-95)ºC heat for 5h and cool for 3h, total 3 times
Salt Spray Test 1.25U0 1000h, no flashover, no breakdown, trip not more than 3 times, no obvious damage
Humidity Test 1.25U0 300h, no flashover, no breakdown, trip not more than 3 times, no obvious damage
Long-time Running Temperature -40ºC to 95ºC
Short Circuit Temperature 250ºC, lasting time less than 5s
Cable Accessories Conductor Material copper, aluminum, copper&aluminum
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
130000000 USD
Plant Area
120000 square meters